FireLite ES-50X Manual⁚ A Comprehensive Guide
Welcome to your go-to resource for the FireLite ES-50X! This manual is designed to offer you detailed insights into the ES-50X addressable fire alarm control panel․ Navigate through essential features, models, programming, and troubleshooting for optimal performance․ Let’s explore the ES-50X system together!
The FireLite ES-50X is a cutting-edge addressable fire alarm control panel (FACP), replacing the MS-9050UD․ Designed for cost-effectiveness and intelligence, the ES-50X boasts a pre-installed communicator card and extensive features․ Supporting up to 50 addressable devices, it accommodates detectors and modules seamlessly․
This FACP is perfect for applications traditionally served by conventional panels, offering advanced capabilities in a compact form․ It’s compatible with both newer Fire-Lite series and legacy 300 Series devices․ The ES-50X comes with a pre-installed IPOTS-COM, providing dual technology (POTS and IP) communication to central stations, saving on dedicated telephone lines․
Optional cellular reporting is also available․ Programming is versatile, allowing local and remote configuration via the FS-Tools Upload/Download utility through a USB port or Ethernet․ The USB port enables easy program, history file, and system voltage downloads․ Encased in a quick-install chassis within a metal cabinet, the ES-50X ensures reliable, long-term performance, making it a dependable fire safety solution․
Key Features of the ES-50X
The FireLite ES-50X boasts numerous features, making it a robust and versatile addressable fire alarm control panel․ It is UL Standard 864, 10th edition listed․ The pre-installed IPOTS-COM offers Ethernet IP and POTS communication to central stations․ For enhanced connectivity, optional cellular communicators are available via AlarmNet․
The ES-50X supports SWIFT wireless devices and features auto-programming for reduced installation time, reporting duplicate device addresses․ It includes two independently programmable NACs configurable as Class A or B․ Strobe synchronization is selectable for System Sensor and Wheelock devices, with EOL resistor matching․
Four programmable function keys simplify maintenance, complemented by two programmable relays and one fixed trouble relay․ An integral 80-character LCD display with backlighting provides clear information․ It stores 1,000 events in its history file and supports multi-criteria detectors for comprehensive detection․ Features include automatic sensitivity testing, device type verification, waterflow selection, alarm verification, and a one-person walk test․ The ES-50X supports up to 16 ANN-BUS annunciators, remote Acknowledge, Alarm Silence, Reset, and Drill․
ES-50X Models⁚ ES-50X, ES-50XC, ES-50XI, and ES-50XP
The FireLite ES-50X series comprises four distinct models, each tailored to meet specific fire safety requirements․ The ES-50X and ES-50XC feature a pre-installed IPOTS-COM, offering dual-path communication via POTS and IP․ The ES-50XI is similar to the ES-50X but designed for international markets, adhering to different regional standards․
The ES-50XP stands out with its integrated CLSS Pathway Pro Communicator, a dual-SIM (ATT/Verizon) 5G LTE-M communicator with optional IP connectivity․ This model facilitates seamless communication between the fire system and the CLSS Cloud, using LTE CAT-M1 networks․ All models support up to 50 addressable devices․
Each variant shares the core capabilities of the ES-50X series, including compatibility with FireLite’s addressable devices, auto-programming, and extensive programming options․ The choice among these models depends on the desired communication method and specific application needs, ensuring a tailored fire safety solution․
Addressable Device Capacity
The FireLite ES-50X series is engineered to support a substantial array of addressable devices, making it a versatile solution for various fire detection needs․ Each panel in the ES-50X family, including the ES-50X, ES-50XC, ES-50XI, and ES-50XP, can manage up to 50 addressable devices connected to a single Signaling Line Circuit (SLC) loop․
This capacity allows for a flexible combination of detectors and modules, tailored to the specific requirements of the protected premises․ The system intelligently integrates both newer Fire-Lite series devices and legacy 300 Series devices, providing seamless compatibility and expansion options․ This ensures that the ES-50X can adapt to evolving needs and incorporate the latest fire detection technologies․
Whether it’s smoke detectors, heat detectors, modules for sprinkler systems, or manual pull stations, the ES-50X’s addressable device capacity offers a customizable and comprehensive fire detection solution for a wide range of applications․
Communication Options⁚ IPOTS-COM and CLSS Pathway Pro
The FireLite ES-50X series offers versatile communication options to ensure reliable reporting of fire events․ The ES-50X and ES-50XC models are equipped with the IPOTS-COM communicator, a dual-technology solution utilizing both POTS (Plain Old Telephone Service) and IP (Internet Protocol) communication paths․
This allows the system to transmit status updates, including alarms, troubles, and AC loss, to a central station via the public switched telephone network․ The IP communicator provides internet monitoring capabilities, sending alarm signals over the internet to reduce reliance on traditional phone lines․ A secondary telephone line can be retained for backup communication․
Alternatively, the ES-50XP features the integrated CLSS Pathway Pro Communicator, a dual-SIM (ATT/Verizon) 5G LTE-M communicator with optional IP connectivity․ This communicator uses LTE CAT-M1 networks to transmit system status to the central station and the CLSS Cloud․ The IP communicator offers internet monitoring for backup communication, ensuring a robust and reliable reporting system․
Programming and Configuration
The FireLite ES-50X offers flexible programming and configuration options to tailor the system to specific installation requirements․ Both remote and local programming are supported through the FS-Tools Upload/Download utility, facilitating efficient system management and maintenance․
Programming databases can be easily uploaded and downloaded via the panel’s USB port using a standard USB cable․ For ES-50X and ES-50XC models, an Ethernet connection via the IPOTS-COM communicator allows for remote programming, streamlining the configuration process․
The USB port also supports the convenient transfer of critical system data using a USB flash drive․ This includes the ability to download or upload the complete program, history file, walk-test data, current status, and system voltages․ This feature simplifies diagnostics, maintenance, and system updates, ensuring the ES-50X operates at peak performance․ Auto-programming, or learn mode, further reduces installation time by automatically detecting and configuring connected devices․
Installation Precautions
Prior to installing the FireLite ES-50X, adhere strictly to the following precautions to ensure a problem-free setup and long-term reliability․ Begin by disconnecting all power sources from the fire alarm control panel before commencing any servicing or installation work․ Multiple power sources can be connected, posing a risk of electrical shock if not properly disconnected․
Ensure that the ES-50X is installed according to all applicable local and national electrical codes and fire safety standards․ Proper grounding is essential to prevent electrical hazards and ensure optimal system performance․ Verify that all wiring connections are secure and correctly terminated to prevent short circuits and communication failures․
Protect the control panel from environmental factors such as excessive moisture, dust, and extreme temperatures․ Mount the ES-50X in a location that allows for easy access for maintenance and inspection․ Following these precautions minimizes potential issues and maximizes the lifespan and effectiveness of your fire alarm system․
Troubleshooting Tips
Encountering issues with your FireLite ES-50X? Start with the basics⁚ verify the power supply is stable and all connections are secure․ Check the system’s display for any error messages or trouble indications․ These messages often provide a starting point for diagnosing the problem․ Next, inspect the SLC loop for any disconnected or malfunctioning devices․
If a specific detector or module is causing issues, try resetting the system to clear any temporary faults․ Ensure that all addressable devices are correctly programmed and configured․ If communication errors persist, examine the wiring for shorts or open circuits․ Consult the ES-50X manual for detailed troubleshooting flowcharts and error code explanations․
For network-related problems, verify the IP or cellular connection․ If using the IPOTS-COM, confirm that the Ethernet cable is properly connected and the network settings are correctly configured․ Also, consider environmental factors that might affect device performance, such as excessive dust accumulation․ Regularly scheduled maintenance is also important․
Manual Download and Support Resources
Accessing the FireLite ES-50X manual is essential for proper installation, programming, and troubleshooting․ You can download the latest version of the ES-50X manual in PDF format from the official FireLite website or authorized distributor sites․ These manuals provide comprehensive details on system operation, wiring diagrams, and configuration settings․
In addition to the manual, FireLite offers a range of support resources to assist users․ Their website features a knowledge base with FAQs, application notes, and technical bulletins․ You can also find helpful videos and tutorials demonstrating various aspects of the ES-50X system․
For personalized assistance, contact FireLite’s technical support team via phone or email․ They can provide expert guidance on troubleshooting complex issues and optimizing system performance․ Remember to have your system model and serial number ready when seeking support․ Consider exploring online forums and communities for additional insights and peer-to-peer support․
Accessories and Optional Equipment
Enhance the functionality of your FireLite ES-50X system with a range of accessories and optional equipment․ Remote annunciators, such as the ANN-BUS series, provide convenient system status and control at various locations within the facility․ These annunciators offer features like alarm silence, reset, and drill functions, improving response times during emergencies․
For expanded communication capabilities, explore cellular communicators via AlarmNet or integrated CLSS Pathway Pro Communicators, dual-SIM (ATT/ Verizon) 5G LTE-M Communicator with optional IP connection․ These communicators ensure reliable reporting to central stations via diverse networks․
Consider adding modules for reverse polarity/city box transmission if required by local regulations․ Also, explore compatible SWIFT wireless devices that can seamlessly integrate into the ES-50X system, offering flexible installation options․ For programming and data management, utilize the FS-Tools Upload/Download utility via USB or ethernet connection, enabling efficient system configuration and maintenance․ Ensure all accessories are UL listed and compatible with the ES-50X for optimal performance․